Product Description
COMPLIANCE
Where sold, compliant with state HFC regulations.
Intertek CCRR-1021;
CCRR-1022 (.56”, .75”);
UL Listings- R11183;
Miami-Dade County, FL (1”, 1.5”, 2”, 3”, 4”);
CA BEARHFTI Lic. No. T 1506.
GreenGuard XPS is not recommended for exterior wall applications
over 6 stories tall. Contact Kingspan for approved applications.
HANDLING & STORAGE
When stored outdoors, XPS should be protected from exposure to direct sunlight using the original packaging or an opaque, light–colored tarp. XPS that has been unwrapped should be covered or rewrapped. XPS left exposed should be covered within 60 days to minimize UV damage. Once the exposed XPS is covered, the damage stops and is limited to the thin layer of cells on the surface that was exposed to the UV. XPS cells below the UV exposed surface layer are generally undamaged and the XPS overall performance remains intact.
WARNING: This product is combustible. A protective barrier or thermal barrier is required as specified in the appropriate building code. Protect it from exposure to open flame or other ignition sources during shipping, storage and installation.